PPG Phenguard Subsea 610 is a subsea primer for the 2-coat system with PPG Phenguard Subsea 780.
Steel should be blast cleaned ion situ to at least ISO Sa2 1/2 with a blasting profile of between 50 - 100 microns. Steel must be free from rust, scale, shop primer and any other contamination. The temperature of the paint should preferably be above 15C otherwise extra thinner may be required to obtain application viscosity.
PPG Phenguard Subsea 610 is used within the following PPG systems:
See Data Sheets tab for System sheet downloadable PDF.
Components: | Two Part |
Type: | High build, amine adduct cured novolac pheonlic epoxy primer |
Finish: | Eggshell |
Stock Colours: | Reddish Grey |
Tintable: | No |
VOC Content: | 315.0g per litre |
Volume Solids: | 66% |
Suitable Substrates: | Steel |
Application Method: | Air Spray, Airless Spray, Brush or Roller |
Theoretical Coverage: | 3.8m2 per litre for 175 microns |
Wet Film Thickness (WFT): | 150 - 500 microns |
Dry Film Thickness (DFT): | 175 microns |
Induction Time: | 15 mins at 20°C |
Pot Life: | 4 hours at 20°C |
Touch Dry: | |
Overcoatable: | Between 3 hours and 21 days at 20°C |
Fully Cured: | 3 days at 20°C |
Cleaner / Thinner: | PPG Thinners 91-92 |
Shelf Life: | 24 months |
Packaging: | Available in 4 and 20 Litres |
The manufacturers data sheets are available for download from this website. It is your responsibility to read and understand all aspects of the data sheets before you place an order and prior to application. Please pay special attention to the preparation, mixing and application temperatures of the product, cleaning of substrate and environmental factors such as temperature, rain etc. Quoted coverage rates are based on the manufacturers theoretical rates and may vary depending upon substrates absorption, texture and application. We always recommend a test is carried out to ensure suitability.